Username Post: New heater motor shaft size bigger than fanblades collar
CurtisLee
Newbie
Posts 30
12-25-21 01:02 PM - Post#2833225    

Used a new 3/8" collar (hole size) and a piece of steel tubing (used in electric lamps to run the cord through) since it was 3/8" outside diameter and drilled inside out to 5/16". Drilled the fan blade base hole out to 3/8". Cut the tubing for the length, about an inch, that needed to go through the collar and fan blade and allowed about a 1/16"+- to stick out above the fan blades base in which I peened this edge out to hold the fan blade to the collar mount (also drilled a hole in the tubing for the collar set screw to go through for securing the fan blades to the motor shaft). Mounted this assembly to the 5/16 shaft of the motor and had a good fit, tested and seemed to work ok.